Six-Year Review 2 Contaminant Occurrence Data (1998-2005)
Second Six-Year Review zip files (grouped alphabetically by chemical names)
Data Elements Contained in the Six-Year Review 2 MS Access files
Table 1: Six-Year Review-ICR Dataset Data Element List - Inventory Data
Data Element | Column Name | Description |
---|---|---|
State Code | STATE | 2- digit state code |
Public Water System Identification Number (PWSID) | PWSID | The code used to identify each PWS. The code begins with the standard 2-character postal state abbreviation or region code; the remaining 7 numbers are unique to each PWS in the state. |
System Name | PWSNAME | Name of the PWS. |
Federal Public Water System Type Code | PWSTYPE | A code to identify whether a system is: • Community Water System (C); • Non-transient Non-community Water System (NTNC); or • Transient Non-community Water System (NC; nitrate/nitrite only). |
Population-served | POPULATION | Highest average daily number of people served by a PWS, when in operation. |
Source Water Type | SRCWATER | Type of water at the source. Source water type can be: • Ground water (GW); or • Surface water (SW); or • Ground water under the direct influence of surface water (GU) |
Table 2: Six-Year Review-ICR Dataset Data Element List - Chemical-Specific Information
Data Element | Column Name | Description |
---|---|---|
State ID | ID | State-specific unique identification code |
Sampling Point Identification Code | SAMPLEPOINTID | A sampling point identifier established by the state, unique within each applicable facility, for each applicable sampling location (e.g., entry point to the distribution system). This information enables occurrence assessments that address intra-system variability. |
Sample Identification Number | SAMPLEID | Identifier assigned by state or the laboratory that uniquely identifies a sample. |
Sample Collection Date | DATE | Date the sample was collected, including month, day, and year. |
Contaminant | CHEMID | 4-digit SDWIS contaminant identification number for which the sample is being analyzed. |
Sample Analytical Result - Sign | DETECT | The sign indicates whether the sample analytical result was: • (0) "less than" means the contaminant was not detected or was detected at a level "less than" the MRL. • (1) "equal to" means the contaminant was detected at a level "equal to" the value reported in "Sample Analytical Result - Value." |
Sample Analytical Result - Value | VALUE | Actual numeric (decimal) value of the analysis for the chemical result, or the MRL if the analytical result is less than the contaminant's MRL. |
Sample Analytical Result - Unit of Measure | UNITS | Unit of measurement for the analytical results reported (usually expressed in either µg/L or mg/L for chemicals; or pCi/L for radionuclides). |